ElectroDesigner — Engineering Software

FAULTCHAIN · BUILD 14

Manufacturer reference catalogue

Exact-source references, not a relabelled generic database.

Current reference coverage: six real product references from the existing starter catalogue, one product family with importable rating records, no complete redistributed manufacturer peak/I²t curve database, and no manufacturer cable thermal profile presented as verified without source evidence.

Build 14 data workflow

FaultChain PRO now includes a manufacturer source-registry viewer and an authorised data-pack importer. Engineers can import exact manufacturer records they are permitted to use into the browser-local My Components library, preserving manufacturer, family/model, source URL, review date and rights/provenance fields. The JSON template shows the supported source structure.

The source registry tracks routes for ABB, Schneider Electric, Eaton, Littelfuse, Mersen, Italweber and ETIM. A registry entry is a provenance/onboarding route, not a claim that the manufacturer has endorsed FaultChain or licensed an embedded commercial database.

Existing real references

ReferencePublished facts currently recordedUse in FaultChain
Mersen AJT200200 A, 600 V AC, published UL interrupting rating 200 kA RMS.Reference/rating evidence; no complete peak or I²t curve embedded.
Littelfuse JTD03030 A, 600 V AC, published 200 kA AC interrupting rating and an isolated total-clearing I²t value at 200 kA.Isolated evidence point; not silently converted into a full curve.
Littelfuse JTD06060 A, 600 V AC, published 200 kA AC interrupting rating and an isolated total-clearing I²t value at 200 kA.Isolated evidence point; not silently converted into a full curve.
Littelfuse JTD100100 A, 600 V AC, published 200 kA AC interrupting rating and an isolated total-clearing I²t value at 200 kA.Isolated evidence point; not silently converted into a full curve.
ABB S204M-C32 / 2CDS274001R032432 A, 4 poles, C characteristic; S200 M-C catalogue Icn 10 kA.Reference only until exact application conditions/curve evidence are attached.
LAPP 1119303 / ÖLFLEX CLASSIC 110 3G1.53G1.5 mm² copper/PVC, 300/500 V product construction reference.Reference only; no k-factor or short-circuit thermal profile inferred from the product name.

Download starter ratings · Download reference index · Open comparison workspace

Commercial-safe rule

Manufacturer names identify products and do not imply endorsement. Public readability of a data sheet does not automatically establish permission to redistribute a protected commercial database or complete curve set. FaultChain therefore keeps generic presets, real factual references, user-imported authorised data and manufacturer-verified packs conceptually separate.

Engineering rule

A part number and interrupting rating do not establish peak let-through or total-clearing energy at every prospective fault level. A single I²t value is a single evidence point. Apparent RMS let-through is not peak current. Missing engineering evidence remains unavailable rather than being estimated under a manufacturer name.

See Data imports and source evidence for the Build 14 import model.